[150-C43NBD] SMC-3 43A Smart Motor Controller
[150-C43NBD]SMC-3 43A Akıllı Motor Kontrol Cihazı
Brand: Allen Bradley
Serial Number: 150-C43NBD
About the Product
Technical and Additional Information
Technical Specifications
With display: | False |
Voltage type for actuating: | AC/DC |
Rated operating voltage Ue: | 200 V |
Rated control supply voltage at AC 50 Hz: | 100 V |
Rated control supply voltage at AC 60 Hz: | 100 V |
Overload current: | 14.3 A |
Controller type: | SMC-3 |
DV/DT protection: | 1000V/µs for power circuit |
Repetitive peak voltage: | 1400V per UL/CSA/NEMA for power circuit |
Operating frequency: | 50/60 Hz per UL/CSA/NEMA for power circuit |
Line connected motor power, max: | 5...15Hp @ 230V AC, 60 Hz, 3-phase |
Delta connected motor power, max: | 7.5...25Hp @ 230V AC, 60 Hz, 3-phase |
Overvoltage category: | III per IEC for side mount auxiliary contacts |
Rated impulse voltage: | 6 kV for power circuit |
Dielectric withstand: | 2500V AC per IEC for power circuit |
Line connected motor current: | 14.3...43A @ 380/400/415/460V AC, 3-phase |
Delta connected motor current: | 25...74A @ 380/400/415/460V AC, 3-phase |
Insulation voltage: | Rated 600V AC per UL/CSA/NEMA for power circuit |
Rated operational voltage: | 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts |
Rated control power during start with fan: | 200mA @ 120V AC/100mA @ 240V AC, 700mA @ 24V AC/DC |
Input OFF-state current: | <10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit |
Short-circuit protection device list: | Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L |
Number of contacts: | TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts |
High capacity available fault current, max: | 70kA @ 600V, maximum current 90 A time delay Class J or Class L fuse for line connected motors |
Type of current: | TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts |
Conventional thermal current (Ith): | TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts |
Type of control circuit: | TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts |
Type of contacts: | TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts |
Utilization category: | TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts |
Rated operational current, max: | TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts |
Standard controller feature: | Soft stop |
Standard available fault current, max: | 10 kA @ maximum standard fuse 250 A for delta device opsal current rating |
Integrated motor overload protection: | True |
Short circuit protection device performance (SCPD) type: | Type 1 |
Selectable overload trip class: | Trip Class 10, 15, or 20 |
Selectable start times: | 2, 5, 10, 15, 20, 25, or 30 s |
Input OFF-state voltage (IN1, IN2), max: | 40V AC @ 17V DC/12V AC for control circuit |
Selectable current limit: | 150%, 250%, 350%, and 450% of full load current |
Input ON-state voltage, during start (IN1, IN2): | 85V AC @ 19.2V DC/19.2V AC minimum for control circuit |
Input ON-state current (IN1, IN2): | 9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit |