[140MP-A3E-C10] Motor Protection Circuit Breaker
[140MP-A3E-C10]Motor Koruma Devre Kesicisi, A Çerçeve, 6,3-10 A, Açma Sınıfı 10A, Standart Kesme Kapasitesi, Standart Manyetik Açma (15 x le'de Sabit)
Brand: Allen Bradley
Product Code: 140MP-A3E-C10
About the Product
Motor Protection Circuit Breaker, motor devrelerinde aşırı yük ve kısa devrelere karşı gelişmiş koruma sağlar. Endüstriyel otomasyon sistemlerinde güvenli ve kesintisiz çalışma sunar. Kompakt tasarımıyla pano içi yerleşimi kolaylaştırır, bakım ihtiyacını en aza indirir. Uzun ömürlü performansıyla güvenilirlik arayanlar için ideal bir çözümdür.
Technical Info
Additional Info
With integrated under voltage release | False |
Rated operating voltage | 0 A |
Type of control element | Turn button |
Type of electrical connection of main circuit | Screw connection |
Rated impulse withstand voltage (Uimp) | 6 kV |
Magnetic trip current | 150 A |
Short circuit current for group motor, max | 18kA @ 480V |
Motor current adjustment range | 6.3...10 A |
Short circuit current Icu, max | 50kA @ 400V |
Rated operational current (Ie) | 10 A |
Ultimate short circuit breaking capacity (Icu) per IEC | 50kA @ 400V AC |
Rated service short circuit breaking capacity (Ics) per IEC | 6kA @ 500V AC |
Insulation voltage (Ui) | Rated 690V |
Hp rating, max | 7.5Hp @ 460V, 3-phase |
KW rating, max | AC-3: 7.5 kW @ 690V, 3-phase |
Short circuit current rating | Type 1 coordination: 5kA @ 600V AC |
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC | 63A @ 500V |
Branch circuit protection per NEC/CEC, max | UL 60947 manual motor controller: 175 A |
Trip class | 10 A |
Fuse or circuit breaker size per NEC, max | UL 60947-4-1 manual motor controller: 175 A |
Short circuit current, max | Type 2 coordination, IEC 60947-4-1: 50kA @ 400V |
Fuse or circuit breaker per NEC, max | UL 60947-4-1 manual motor controller: 175 A |
Short circuit current for group motor installation, max | UL 60947 manual motor controller: 5kA @ 600V |
Short circuit current for motor disconnect, max | UL 60947 manual motor controller: 5kA @ 600V |
Number of poles | 3 |
With thermal protection | True |
Phase failure sensitive | True |
Max current Ie | 32 A |
Maximum operating voltage (UL) | 600 V |
Disconnect function per IEC/EN 60947-2 | True |
Rated operating voltage (Ue) | 690V AC |
Rated frequency | 50/60 Hz |
Number of operations | Mechanical: 100.000 cycles, Electrical: 100000 cycles (0.1...16 A), 50000 cycles (20...32 A) |
Power loss | 5.1 W @ 0.16...1.6 rated operating current, 5.4 @ 2.5...6.3 rated operating current, 7.2 @ 10...12 rated operating current, 8.4 @ 16...25 rated operating current, 9.3 @ 32 rated operating current |