[150-C43NBD] SMC-3 43A Smart Motor Controller

[150-C43NBD]SMC-3 43A Akıllı Motor Kontrol Cihazı

Brand: Allen Bradley

Serial Number: 150-C43NBD

https://erp.patrion.net/web/image/product.template/804/image_1920?unique=4ee4e6d

    Bu kombinasyon mevcut değil.

    About the Product

    Technical and Additional Information
    Technical Specifications
    With display: False
    Voltage type for actuating: AC/DC
    Rated operating voltage Ue: 200 V
    Rated control supply voltage at AC 50 Hz: 100 V
    Rated control supply voltage at AC 60 Hz: 100 V
    Overload current: 14.3 A
    Controller type: SMC-3
    DV/DT protection: 1000V/µs for power circuit
    Repetitive peak voltage: 1400V per UL/CSA/NEMA for power circuit
    Operating frequency: 50/60 Hz per UL/CSA/NEMA for power circuit
    Line connected motor power, max: 5...15Hp @ 230V AC, 60 Hz, 3-phase
    Delta connected motor power, max: 7.5...25Hp @ 230V AC, 60 Hz, 3-phase
    Overvoltage category: III per IEC for side mount auxiliary contacts
    Rated impulse voltage: 6 kV for power circuit
    Dielectric withstand: 2500V AC per IEC for power circuit
    Line connected motor current: 14.3...43A @ 380/400/415/460V AC, 3-phase
    Delta connected motor current: 25...74A @ 380/400/415/460V AC, 3-phase
    Insulation voltage: Rated 600V AC per UL/CSA/NEMA for power circuit
    Rated operational voltage: 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
    Rated control power during start with fan: 200mA @ 120V AC/100mA @ 240V AC, 700mA @ 24V AC/DC
    Input OFF-state current: <10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit
    Short-circuit protection device list: Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
    Number of contacts: TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
    High capacity available fault current, max: 70kA @ 600V, maximum current 90 A time delay Class J or Class L fuse for line connected motors
    Type of current: TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
    Conventional thermal current (Ith): TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
    Type of control circuit: TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
    Type of contacts: TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
    Utilization category: TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
    Rated operational current, max: TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
    Standard controller feature: Soft stop
    Standard available fault current, max: 10 kA @ maximum standard fuse 250 A for delta device opsal current rating
    Integrated motor overload protection: True
    Short circuit protection device performance (SCPD) type: Type 1
    Selectable overload trip class: Trip Class 10, 15, or 20
    Selectable start times: 2, 5, 10, 15, 20, 25, or 30 s
    Input OFF-state voltage (IN1, IN2), max: 40V AC @ 17V DC/12V AC for control circuit
    Selectable current limit: 150%, 250%, 350%, and 450% of full load current
    Input ON-state voltage, during start (IN1, IN2): 85V AC @ 19.2V DC/19.2V AC minimum for control circuit
    Input ON-state current (IN1, IN2): 9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
    Additional Information